Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply Automatic Transfer Switch ATS WCQ2C Double Power Supply

Automatic Transfer Switch ATS WCQ2C Double Power Supply

Key Information

WCQ2C

Pole: 2P,3P, 4P

Voltage: AC400V

Icm:7.5KA-63KA

Inm(A): 63

In(A): 6-63

General

WCQ2 series double power supplies automatic transfer switch (ATS) applies to AC50Hz, rated operation voltage 400V, rated operation current 16A to 2000A, to two circuits power supply of emergency power supply system. It can be set as manual of the mutual transfer between frequent-use and backup power supply, as circuit controlling switch of control, signal, and interlock functions. Some types of the product have communication ports to make it realisable of remote control and unattended substation to the user. It applies to residence community, military facility, hospital, mall, airport, etc.,

The ATS meets standards IEC/EN60947 and GB/T14048.11

Main technical parameters

ModelWCQ2C
Rated short circuit breaking capacity5kA
Rated short circuit connecting capacity7.5kA
Transfer time≤3S
Controlling voltage of changeover switchAC230V
Mechanical life3000 times
Electrical life1500 times
Rated insulation voltageU=690V
Rated operation current10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Usage catagoryAC-33B
Test condition of connecting and breakingI/Ie6.0
U/Ue1.05
Cos40.5
Power-on time0.05s
Circle ≤5min
Operation circle times12

Note: AC-33B motor load or mixed load of motor and resistance under infrequent operation.


Contact Us

Contact: westhomes

Phone: 0097142210039/0097142297823

Tel: 05666-16680

E-mail: westhomeshhz@gmail.com

Add: Show Room No.1-Sabkha UAE SHOWROOM